ADA Railings
Upright Steel fabricates and installs ADA railings in Cleveland, Ohio: ramp railings, stair handrails and wall-mounted handrails built to the 2010 ADA Standards for Accessible Design and the accessibility provisions of the Ohio Building Code. We work with businesses, churches, schools, property managers and contractors, on new construction and on retrofits to existing entrances.

ADA Railings Do More Than Pass Inspection
Handrails on ramps and stairs give people with limited mobility, low vision or balance concerns something solid to hold. They also help parents with strollers, older visitors and anyone walking on an icy Cleveland morning. An ADA compliant railing has the right height, grip size, wall clearance and extensions, and small mistakes in any of those can fail an inspection or create an access complaint.
ADA Handrail Requirements We Build To
Key handrail provisions from the 2010 ADA Standards (Section 505), which align closely with ICC A117.1 as referenced by the Ohio Building Code:
Height: 34 to 38 in.
Measured vertically to the top of the gripping surface from the ramp surface or the stair tread nosings, and kept consistent along the run.
Gripping surface
Circular rails between 1-1/4 and 2 in. outside diameter, continuous and unobstructed along the top and sides. Standard 1-1/2 in. Schedule 40 pipe (1.90 in. OD) fits this range.
Wall clearance: 1-1/2 in. min.
At least 1-1/2 in. of clear space between the handrail and the wall or any adjacent surface.
Extensions
Ramp handrails extend 12 in. horizontally past the top and bottom of each run. Stair handrails extend 12 in. at the top, and at the bottom continue at the slope for one tread depth past the last nosing.
Both sides & continuous
Ramps with a rise over 6 in. need handrails on both sides, and handrails must be continuous along each ramp run and stair flight.
Fixed & secure
Handrails can’t rotate in their fittings, and ends return smoothly to the wall, floor or post so nothing catches clothing or bags.
Ramps also need edge protection, and drop-offs over 30 in. need a full-height guard, usually 42 in., in addition to the handrail. We design ramp railings that combine both.
ADA Railings & Handrails We Fabricate
- Ramp railings with combined guard and handrail
- Stair handrails for interior and exterior stairs
- Wall-mounted handrails with ADA-compliant brackets and returns
- Intermediate (center) handrails for wide stairs
- Retrofit handrails for existing entrances, churches, schools and storefronts
- Steel, galvanized steel and stainless steel, with paint, powder coat or brushed finishes

How We Build ADA Railings in Our Cleveland Shop
- Measure & review — We measure the ramp or stair, slope, landings and walls, and flag existing conditions that affect compliance.
- Layout & drawings — Rails, posts, extensions and returns are laid out to meet the ADA Standards and the building code.
- Fabricate & finish — We cut, bend and weld in our Cleveland shop, then finish with galvanizing, paint or powder coat.
- Install — We anchor posts and brackets into concrete, masonry or framing and check heights and clearances before we leave.
ADA Railings Fabricated & Installed in Cleveland
Handrails and guardrails have been a specialty of ours since 2004. Because we fabricate in Cleveland and install with our own crew, we can retrofit an entrance quickly and keep your doors open while we work.
We install ADA railings and handrails in Cleveland, Ohio and throughout Northeast Ohio, including:
- Cleveland
- Lakewood
- Parma
- Independence
- Garfield Heights
- Euclid
- Shaker Heights
- Solon
- Strongsville
- Westlake
- Mentor
- Medina
- Akron
- Lorain & Elyria
ADA Railing FAQs
What height do ADA handrails need to be?
Under the 2010 ADA Standards, the top of the handrail gripping surface must be 34 to 38 inches above the ramp surface or stair nosings, measured vertically, and consistent along the run.
Do ADA ramps need handrails on both sides?
Yes. Ramp runs with a rise greater than 6 inches require handrails on both sides. Stairs that are part of an accessible route also need handrails on both sides.
What diameter should an ADA handrail be?
Circular handrails must have an outside diameter between 1-1/4 and 2 inches. Standard 1-1/2 inch Schedule 40 steel pipe, with an outside diameter of 1.90 inches, is a common compliant choice.
Do ADA handrails need extensions?
Yes. Ramp handrails extend 12 inches horizontally beyond the top and bottom of the ramp run. Stair handrails extend 12 inches horizontally at the top, and at the bottom continue at the stair slope for one tread depth past the last riser nosing.
Can you add ADA handrails to an existing ramp or entrance?
Yes. Retrofits are a big part of our ADA work. We measure the existing ramp or stair and fabricate rails that meet the requirements and fit the existing concrete, masonry and walls.
More Railing & Stair Services
ADA railings we install in Cleveland, Ohio are built to the 2010 ADA Standards for Accessible Design. The U.S. Access Board also publishes plain-language guides for ramps and stairways.
Get a Quote on ADA Railings in Northeast Ohio
Need ADA railings for a ramp or stair in Cleveland, Ohio? Send photos of your ramp or stairs, with approximate lengths if you have them, and we’ll follow up to measure and quote compliant railings.